跳到正文
← 返回论文列表与筛选
阅读说明

本页整理公开书目信息,不生成学术质量评分。AI 解读根据题名及所注明的摘要或原文片段生成,未完成全文核验,可能有误;具体假设、证明与结论请核对原文。摘要保留来源文本,未经模型改写。

DOI 首次登记不等于接收或发表日期。部分更正、评论等条目没有独立摘要;缺少可靠材料时保留待补状态。

引用量采用 OpenAlex 单条关联记录,不合计多个记录;关联记录可能包含正式发表版本,不等于此版本单独引用。缺失不视为零,引用指标不代表论文质量。

关注作者按书目中的完整姓名匹配,同名和姓名变体需人工辨别。相关论文先按共享细分方向和具体方法排列,再参考通用方法与发表日期。

分类依据与纠错

AI 根据所提供的论文材料归类:摘要聚焦环境数据的可扩展加性建模,日度观测与监测站结构不足以归入宏观时间序列或面板方向。

反馈分类问题

正在核对关联版本…

代码、数据与补充材料

正在核对对应版本的资源…

关注这篇论文的作者
Simon N. Wood
Zheyuan Li
Gavin Shaddick
Nicole H. Augustin

海量数据的广义加性模型:英国黑烟监测网日度数据建模

研究问题
如何在大规模日度污染监测资料上拟合复杂广义加性模型,支持趋势、空间分布和局部日暴露估计,同时控制内存与计算成本?
方法与思路
作者结合新的系数与平滑参数迭代方案、块 Cholesky 等运算的并行化,以及协变量边际离散化和高效交叉乘积计算。
材料陈述的贡献
摘要称,这些方法使英国黑烟日度模型能在桌面工作站上计算,并相较所述既有低内存方法大幅减少计算时间。
阅读关注点
应核对边际离散化引入的近似误差、迭代与平滑参数估计的稳定性,以及时间和内存比较的硬件、模型与基准设置。
阅读边界
仅据版本未注明的 OpenAlex 索引摘要;规模数字“104”“108”的指数表示不清,需查阅原 PDF,不能据此重构数据规模。

原文摘要

We develop scalable methods for fitting penalized regression spline based generalized additive models with of the order of 104 coefficients to up to 108 data. Computational feasibility rests on: (i) a new iteration scheme for estimation of model coefficients and smoothing parameters, avoiding poorly scaling matrix operations; (ii) parallelization of the iteration’s pivoted block Cholesky and basic matrix operations; (iii) the marginal discretization of model covariates to reduce memory footprint, with efficient scalable methods for computing required crossproducts directly from the discrete representation. Marginal discretization enables much finer discretization than joint discretization would permit. We were motivated by the need to model four decades worth of daily particulate data from the U.K. Black Smoke and Sulphur Dioxide Monitoring Network. Although reduced in size recently, over 2000 stations have at some time been part of the network, resulting in some 10 million measurements. Modeling at a daily scale is desirable for accurate trend estimation and mapping, and to provide daily exposure estimates for epidemiological cohort studies. Because of the dataset size, previous work has focused on modeling time or space averaged pollution levels, but this is unsatisfactory from a health perspective, since it is often acute exposure locally and on the time scale of days that is of most importance in driving adverse health outcomes. If computed by conventional means our black smoke model would require a half terabyte of storage just for the model matrix, whereas we are able to compute with it on a desktop workstation. The best previously available reduced memory footprint method would have required three orders of magnitude more computing time than our new method. Supplementary materials for this article are available online.

笔记与分组
相关领域论文