A Study of Least Squares and Maximum Likelihood for Image Reconstruction in Positron Emission Tomography
正电子发射断层成像重建中的最小二乘与最大似然比较AI 解读 ↓
本页整理公开书目信息,不生成学术质量评分。AI 解读根据题名及所注明的摘要或原文片段生成,未完成全文核验,可能有误;具体假设、证明与结论请核对原文。摘要保留来源文本,未经模型改写。
DOI 首次登记不等于接收或发表日期。部分更正、评论等条目没有独立摘要;缺少可靠材料时保留待补状态。
引用量采用 OpenAlex 单条关联记录,不合计多个记录;关联记录可能包含正式发表版本,不等于此版本单独引用。缺失不视为零,引用指标不代表论文质量。
关注作者按书目中的完整姓名匹配,同名和姓名变体需人工辨别。相关论文先按共享细分方向和具体方法排列,再参考通用方法与发表日期。
AI 根据所提供的论文材料归类:摘要研究医学成像逆问题及重建算法,未提供与所列经济学领域细分的直接联系。
正电子发射断层成像重建中的最小二乘与最大似然比较AI 解读 ↓
正在核对关联版本…
正在核对对应版本的资源…
Positron emission tomography (PET) is a radiologic tool offering a unique capability for measuring tissue metabolism in vivo. A number of biological and physical factors limit the resolution of PET so often the statistical aspects of image reconstruction have an appreciable effect on the quality of information obtained from a study. To a first approximation, reconstruction involves the solution of a linear inverse problem with a line-integral Radon-type transform. Standard filtered back-projection reconstruction is based on the method of least squares. Although computationally efficient, the method does not enforce positivity constraints leading to undesirable negative artifacts in the results. Maximum likelihood based approaches to reconstruction do not suffer from this problem, but their computational complexity has limited the ability to determine quantitatively the improvements in image quality. In this paper, asymptotic approximations and numerical simulations are used to examine the least squares and maximum likelihood methods in some detail. The studies are carried out for idealized representations of conventional and time-of-flight tomographs. The asymptotic analysis indicates that for a range of Sobolev norms the rates of estimation of least squares and maximum likelihood reconstructions are of the same order. This is borne out by numerical studies. However, in these studies maximum likelihood is found to be more efficient than least squares: on a conventional distance-angle tomograph, the root mean square error is on the order of 10-20% smaller for maximum likelihood reconstructions. The corresponding reduction in the root mean square error on a time-of-flight tomograph is in the 5% range. Similar results are found using more complex region of interest based measures of reconstruction accuracy. In addition it is found that much of the effect of maximum likelihood can apparently be realized by postprocessing least squares solutions in an ad hoc manner to reduce negativity artifacts. Since the postprocessing scheme is computationally fast, this suggests that in PET it may be possible to realize the benefits of maximum likelihood without the substantial computational overhead of the EM algorithm.